banner



How To Replace Watts Premier Filters

Watts Premier has many different options for yous when it comes to replacing your Filters. We offer the Filters individually or in Filter Kits in order to fit your needs. Run into all of the different stages below for your RO Pure Plus Reverse Osmosis Organization to assist you locate the Filter or Filter Kit you are looking for.

  • Private Stages of Your RO Pure Plus Contrary Osmosis System

    Stage #ane - Five Micron Sediment Filter (105311) that traps sediment and other particulate matter like dirt, silt and rust which affect the taste and appearance of your water. Note - Recommended Alter Every 6 Month.

    Phase #2 - Five Micron Carbon Block Filter (105351) which helps ensure that chlorine and other materials that cause bad taste and odor are profoundly reduced. Note - Recommended Change Every 6 Month.

    Phase #3 - 50 GPD (Gallons Per Day) RO Membrane (105331) the heart of the Reverse Osmosis Organization. This semi permeable membrane volition effectively remove TDS, Sodium and a wide range of contaminants such every bit Chromium, Arsenic, Copper, Lead equally well as Cysts, such equally Giardia and Cryptosporidium. Because the process of extracting this high quality drinking water takes time, your RO water treatment system is equipped with a storage tank. Note - Recommended Change Every 2 to 5 Years depending on your water quality.

    Stage #4 - VOC (Volatile Organic Compound) Carbon Block Filter (105381). Through the specialty (VOC) like MTBE'southward, Atrazine, Benzene, 2,4-D,Lindane and others from your drinking water. It is estimated that VOC'south are present in one-5th of the nation'southward h2o supplies. These water contaminants tin can enter basis h2o from a variety of sources including localized use of herbicides and pesticides, gasoline or oil spills, leaking hole-and-corner fuel tanks, septic system cleaners, and chemicals used in the dry out-cleaning industry. Premier RO-Pure Plus arrangement conforms to NSF/ANSI 58 for VOC reduction. Run across performance data sheet for individual contaminants and reduction performance. Note - Recommended Modify Every 12 Months.

  • Filter Kits Without Membrane

    Bi-Almanac Filter Kit - 531102 - This kit contains one sediment Filter (105311) and one Pre-Carbon Filter (105351).

    Annual Filter Kit - 531109 - This kit contains two Sediment Filters, (105311), two Pre-Carbon Filters (105351) and one VOC Carbon Block Filter (105381).

  • Filter Kits With Membrane

    Four Pack Filters - 531160 - This kit contains one Sediment Filter (105311), i Pre-Carbon Filter (105351), one VOC Carbon Cake Filter (105381) and one 50 GPD Membrane (105331).

    Six Pack Filters - 531161 - This kit contains two Sediment Filters (105311), 2 Pre-Carbon Filters (105351), one VOC Carbon Block Filter (105381) and one 50 GPD Membrane (105331).

Your Systems Operating Parameters and Organization Diagram will assist you go along your Reverse Osmosis functioning to it fullest capacity. If you have whatsoever questions you lot can contact us at 1-800-752-5582 or email usa at WeCare@WattsWater.com and we will get back with you as shortly as possible.

  • Operational Parameters

    Hardness - Recommended hardness not to exceed 10 grains per gallon, or 170 parts per million. Organization will operate with hardness over 10 grains but the membrane life may be shortened. Addition of a water softener may lengthen the membrane life.

    Water Pressure - The operating water pressure in your dwelling should be tested over a 24 hour period to attain the maximum pressure. If the incoming water pressure is above 100 psi and then a water force per unit area regulator is required. A booster pump is needed for incoming water pressure level under 40psi.

    Copper Tubing - Opposite Osmosis h2o should not be run through copper tubing as the purity of the water will leach copper causing an undesired gustatory modality in water and pin holes may form in the tube.

Parameter Minimum Maximum
Operating Temperatures: 40°F (four.four°C) 100°F (37.8°C)
Operating Pressure: 40 psi (2.fourscore kg/cm2) 100 psi (vii.0 kg/cm2)
pH Parameters: 2 11
Atomic number 26: N/A 0.2 ppm
TDS (Total Dissolved Solids): North/A <1800 ppm
Turbidity: North/A <5NTU
Hardness N/A 10 Grains Per Gallon
  • System Diagram

Watts Premier RO Pure Plus System Diagram

Diagram Number Part Number Description
1 115304 Filter Hat
ii 134003 Automatic Shut-Off Valve
three 119007 Storage Tank - 3 Gallons
iv 560080 Adapt-A-Valve Kit
5 116187 Summit Mount Twist Faucet
6 134018 Tank Valve - ¼F x ¼" QC
vii 134018 Drain Saddle
8 142000 ¼" Green Tubing with 90° bend - 4'
9 142001 ¼" Blueish Tubing with 90° curve - iv'
10 105331 ⅜ Blackness Tubing - 3' X 1
11 142002 ¼" Crimson Tubing with 90° bend - 4'
12 105311 Sediment Pre-Filter (Red)
13 105351 Carbon Pre-Filter (Yellowish)
14 105331 Membrane l GPD (Green)
xv 105381 VOC Carbon Post Filter (Silver)

Watts Premier has laid out every contaminant which is reduced by your RO Pure Plus Opposite Osmosis Organisation. If you can't detect the information you are looking for our tech support agents volition assist you. You can contact us at 1-800-752-5582 or email us at WeCare@WattsWater.com and nosotros will get back with you every bit soon every bit possible.

Note - Depending on water chemistry, water temperature, and h2o pressure level Premier'southward R.O. Systems production and performance will vary.

  • Performance Data Canvass

Substance % Reduction Inf. Challenge Concentration Max. Allowable Concentration (MG/L)
Arsenic (Pentavalent) 98.80% 0.30 +/- 10% 0.010
Barium 97.60% 10.0 +/- x% two.0
Cadmium 95.lxx% 0.3 +/- 10% 0.005
Chromium (Hexavalent) 98.50% 0.03 +/- ten% 0.1
Chromium (Trivalent) 96.70% 0.03 +/- ten% 0.ane
Copper 98.70% 3.0 +/- 10% i.3
Cysts 99.97% min. 50,000/mL N/A
Fluoride 95.70% viii.0 +/- ten% ane.v
Lead 95.70% 0.15 +/- 10% 0.0107
Perchlorate 96.90% N/A Due north/A
Radium 226/228 80.0% 25 pCi/50 5 pCiL
Selenium 96.50% 0.10 +/- 10% 0.05
TDS 96.40% 750 +/- 40 mg/L 187
Turbidity 99.0% xi +/- 1 mg/L 0.five NTU
Nitrate / Nitrite 83.30% N/A N/A
*VOC (as chloroform) 99.80% 300 +/- thirty 0.5
Recovery - 25.5% Daily Production Charge per unit - 23.five GPD Efficiency - 12.8%
  • Arsenic Fact Canvass

    Arsenic (As) is a naturally occurring contaminant constitute in many footing waters. Arsenic in h2o has no color, taste or scent. It must be measured by an arsenic test kit or lab test.

    Public water utilities must accept their water tested for arsenic. You can obtain the results from your h2o utility independent within your consumer confidence study. If you accept your ain well, you lot will need to have the h2o evaluated. The local health department or the state environmental health agency can provide a listing of test kits or certified labs.

    There are 2 forms of arsenic: pentavalent arsenic (likewise chosen Every bit (V), As (+5)) and trivalent arsenic (as well called Every bit (3), As (+iii)). In well water, arsenic may be pentavalent, trivalent, or a combination of both. Although both forms of arsenic are potentially hazardous to your wellness, trivalent arsenic is considered more than harmful than pentavalent arsenic. RO systems are very constructive at removing pentavalent arsenic. Free chlorine residual volition rapidly convert trivalent arsenic to pentavalent arsenic. Other water handling chemicals such equally ozone and potassium permanganate will likewise change trivalent arsenic to pentavalent arsenic. A combined chlorine residuum (also chosen chloramine) where it does convert trivalent arsenic to pentavalent arsenic, may not convert all the trivalent arsenic in to pentavalent arsenic. If you lot get your h2o from a public water utility, contact the utility to find out if gratuitous chlorine or combined chlorine is used in the water organization.

    This Watts Premier Reverse Osmosis Organization is designed to remove up to 98% of pentavalent arsenic. It volition not convert trivalent arsenic to pentavalent arsenic. Under laboratory standard testing conditions, this organization reduced 0.30 mg/L (ppm) pentavalent arsenic to under 0.010 mg/Fifty (ppm) (the USEPA standard for drinking h2o). Actual performance of the system may vary depending on specific water quality conditions at the consumer's installation. In add-on to the independent laboratory standard testing weather condition, Watts Premier has conducted boosted field testing on our Reverse Osmosis Systems to determine trivalent arsenic reduction capabilities. Based upon Watts Premier'southward field testing, it has been determined that the RO units are capable of reducing upwardly to 67% of trivalent arsenic from the drinking water.

    This Reverse Osmosis System contains a replaceable component critical to the efficiency of the organisation. Replacement of the reverse osmosis component should be with ane of identical specifications, as divers by the manufacturer, to ensure the same efficiency and contaminant reduction functioning.

Watts Premier'south 1 Year Warranty is meant to protect our customers from any unexpected defects in workmanship (excluding Filters and Membranes). If you accept any questions regarding your warranty you can contact us at ane-800-752-5582 or email u.s. at WeCare@WattsWater.com and we volition get back with you as shortly as possible.

  • What Your Warranty Covers

    If any part of your RO PURE PLUS is defective in workmanship (excluding replaceable filters), return unit of measurement after obtaining a render authorization (see beneath), Inside 1 Year of the Original Retail Buy , Watts Premier volition repair or, at Watts Premier'south selection, replace the system at no accuse.

  • How To Obtain Warranty Service

    For warranty service, call 800-752-5582 for a return authorisation number. Then, ship your unit of measurement to our mill, freight and insurance prepaid, with proof of date of original buy. Please include a note stating the problem. Watts Premier will repair it, or supersede it, and transport information technology back to you prepaid.

  • What This Warranty Does Not Cover

    This warranty does non cover defects resulting from improper installation, (contrary to Watts Premier printed instructions), from abuse, misuse, misapplication, improper maintenance, neglect, alteration, accidents, casualties, burn down, overflowing, freezing, environmental factors, water pressure spikes or other such acts of God.

    This warranty volition exist void if defects occur due to the failure to observe the post-obit conditions:

    #1 - The Reverse Osmosis System must be hooked upward to a potable municipal or well cold h2o supply.

    #2 - The hardness of the h2o should not exceed 10 grains per gallon, or 170 ppm.

    #3 - Maximum incoming iron must be less than 0.2 ppm.

    #4 - The pH of the h2o must non exist lower than 2 or higher than 11.

    #5 - The incoming water pressure level must be between twoscore and 100 pounds per square inch.

    #6 - Incoming water to the RO cannot exceed 100 degrees F (40 degrees C.)

    #7 - Incoming TDS (Total Dissolved Solids) not to exceed 1800 ppm.

    #8 - Practice not use with water that is micro biologically dangerous or of unknown quality without acceptable disinfection before or later the system.

    This warranty does not cover any equipment that is relocated from the site of its original installation. This warranty does not cover whatsoever charges incurred due to professional installation. This warranty does not cover any equipment that is installed or used outside the United states and Canada.

  • Limitations and Exclusions

    Watts Premier Will Not Be Responsible For Whatsoever implied Warranties, Including Those of Merchant-ability and Fitness for a Detail Purpose. Watts Will Non Be Responsible for Whatever Incidental or Consequential Amercement, Including Travel Expense, Telephone Charges, Loss of Revenue, Loss of Time, Inconvenience, Loss of Use of the Equipment and Damage Acquired by this Equipment and its Failure to Part Properly. This Warranty Sets Forth All of Watts Premier's Responsibilities Regarding This Equipment.

  • Other Weather

    If Watts Premier chooses to replace the equipment, Watts Premier may supplant it with reconditioned equipment. Parts used in repairing or replacing the equipment will exist warranted for 90 days from the date the equipment is returned to y'all or for the residual of the original warranty menstruum, whichever is longer. This warranty is not assignable or transferable.

  • Your Rights Under Country Law

    Some states exercise non allow limitations on how long an implied warranty lasts, and some states exercise not let the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not use. This warranty gives y'all specific legal rights, and you may take other legal rights which vary from state to country.

How To Replace Watts Premier Filters,

Source: https://www.premierh2o.com/pages/531417-ro-pure-plus-guide